Author Archives: admin

Real Estate Transactions with Fire Sprinkler Systems

Quite often real estate transactions take place that leave the end user or purchaser/occupant unaware that they have issues pending that require resolution with their newly acquired property, that could be costly and are still unresolved. When properties go through … Continue reading

Posted in Sprinklers | Tagged | Leave a comment

Fire System Maintenance Riverside County

Fire sprinkler, Fire alarm, and all life safety devices are no different than any other mechanical device manufactured. Required inspections of these devices are no different than oil changes and break services for your automobile. If maintenance and care are … Continue reading

Posted in Sprinklers | Tagged , | Leave a comment

Residential Fire Sprinkler Repairs

Yes We Do!!! Precision Fire Systems repairs residential & commercial fire sprinkler systems. We repair and install fire sprinkler systems whatever time the call comes in 24/7. Many times when arriving to a leak repair on residential fire sprinklers the … Continue reading

Posted in Sprinklers | Tagged , , | Leave a comment

Moreno Valley Multi-Family Residential Housing

Multi-Family Residential Housing Inspection Program In 2011, the Moreno Valley Fire Department instituted a Multi Family Residential Housing Inspection Program. California Health & Safety Code Section 13146.2 mandates that the Fire Department inspect multi-family housing units for compliance with the … Continue reading

Posted in Sprinklers | Tagged , , , , , , , , , , , | Leave a comment

Amerex, Ansul, RangeGuard or Pyrochem

“I just found out that my restaurant has a kitchen fire suppression system that does not meet the UL300 UL 300 requirements… What’s it going to Cost Me?” Amerex KP, Ansul R102, Range-Guard, or Pyro-Chem Fire Suppression Systems – which … Continue reading

Posted in How to, UL300 Fire Suppression Systems | Tagged , , , , , , | Leave a comment

Backflow Conditions

Water is designed to flow in ONE direction once it leaves the city water main and into the various plumbing and fire sprinkler systems. Water is NEVER permitted to flow backwards creating a backflow condition. A backflow preventer device is … Continue reading

Posted in Backflow Preventer, Sprinklers | Tagged , , , , , , | Leave a comment

Main Drain Test

Main Drain Tests of fire sprinkler systems are required during the annual inspection and does a lot more than many fire sprinkler technicians are even aware of. The main drain test is the first outlet on the system side of … Continue reading

Posted in Sprinklers | Tagged , , , , , , | Leave a comment

Fire Sprinkler Alarm Check Valve

Fire Sprinkler Systems require a “local” bell on-site to sound should a fire sprinkler activate that will notify tenants and surrounding occupants “FIRE” “Call 911″. In a commercial building from as early as the 60′s & 70′s it was really … Continue reading

Posted in Backflow Preventer, Sprinklers | Tagged , , , , , , , , , , , | Leave a comment

Fire Sprinkler Systems Orange County

“Fire Sprinkler Systems Orange County, Fire Sprinkler Systems Orange County, Fire Sprinkler Systems Orange County Fire Sprinkler Systems Orange County Fire Sprinkler Systems Orange County, Fire Sprinkler Systems Orange County, Fire Sprinkler Systems Orange County Fire Sprinkler Systems Orange County,Fire … Continue reading

Posted in Sprinklers | Tagged , | Leave a comment

What is NFPA 13d

Design of Residential Fire Sprinklers falls under NFPA 13d. Can some please define – What is NFPA 13d? Originally One & Two Family Dwellings would only require fire sprinkler systems when the house exceeded 5,000 square feet, or the developer/community … Continue reading

Posted in Sprinklers | Tagged , , , | Leave a comment